Iridex Oculight Slx

Iridex OcuLight® SLx

810 nm Infrared Solid-State Laser

The Industry Standard for High-Performance Versatility
Oculite Slx

Oculite Slx

The Industry Standard for High-Performance Versatility

The OcuLight® SLx 810 nm infrared laser offers high performance for retinal photocoagulation and glaucoma procedures, including transscleral applications. The versatile capability of the OcuLight SLx system offers three different laser energy delivery modalities: CW-Pulse™, MicroPulse™, and LongPulse™. The system’s highly ergonomic user interface, infrared wavelength, and wide choice of delivery systems offer a broad spectrum of treatment options particularly well suited for retinopathy of prematurity and end-stage glaucoma. Indications for Use Indication Procedure Delivery Device Glaucoma Laser Trabeculoplasty; Iridotomy; Slit Lamp Adapters (SLAs); G-Probe™ – Primary Open Angle Transscleral Cyclophotocoagulation – Closed Angle – Refractory Glaucoma Diabetic Retinopathy Panretinal Photocoagulation (PRP); SLA; EndoProbe®; – Nonproliferative Retinopathy Focal and Grid Laser Treatments Laser Indirect Ophthalmoscope (LIO) – Macular Edema – Proliferative Retinopathy Retinal Tears, Detachments, and Holes Transscleral Retinal Photocoagulation SLA; DioPexy™; LIO; EndoProbe (TSRPC); Focal and Grid Laser Treatments Lattice Degeneration PRP; Focal and Grid Laser Treatments EndoProbe; SLA; LIO Age-Related Macular Degeneration (AMD) Focal and Grid Laser Treatments SLA; LIO Intra-Ocular Tumors Focal and Grid Laser Treatments SLA; LIO; Operating Microscope – Choroidal Hemangioma Adapter (OMA) – Choroidal Melanoma – Retinoblastoma Retinopathy of Prematurity PRP; TSRPC; Focal and Grid Laser Treatments DioPexy; LIO; LIO-LS Sub-Retinal (choroidal) Focal and Grid Laser Treatments SLA; LIO Neovascularization Central and Branch Retinal Vein PRP; Focal and Grid Laser Treatments EndoProbe; SLA; LIO Occlusion Specifications Wavelength: 810 nm Infrared Weight: 14.0 lb (6.4 kg) Dimensions: 4″ H x 12″ W x 12″ D (10 cm x 30 cm x 30 cm) Connector Type: Resistor Electrical: 100–120 VAC, 50/60 Hz 200–240 VAC, 50/60 Hz Exposure Duration: CW-Pulse™: 10–9000 ms LongPulse™: 10 s–30 min Exposure Interval: 50–1000 ms MicroPulse™ Duration: MicroPulse: 0.1–1.0 ms MicroPulse Interval: MicroPulse: 1.0–10.0 ms Aiming Laser: Diode laser, 655 nm nominal Delivery Device Portable SLA: 0–2000 mW Power Output: LIO: 0–2000 mW LIO-LS: 0–2000 mW EndoProbe®: 0–2000 mW G-Probe™: 0–3000 mW DioPexy™: 0–2000 mW OMA: 0–2000 mW